1. Overview
LGFA-WB receives signals from Dancer-Sencor attached to the winder and controls the winding motor.
A signal converter that generates a speed control signal suitable for a speed control device (mainly an inverter).
(Signal-Controller)
This product has the following features added to make it even more convenient to use than existing imported products.
A DVM (Digital Volt Meter) is attached to display the output voltage, so you can immediately check the operating status during adjustment or use.
It has a built-in overcurrent protection circuit and indicator lamp, so it does not malfunction even if there is a wiring error or short circuit on the output side.
2. Installation
When installing this product, please note the following:
Please install this product in a location with little dust, low temperature and humidity, and little vibration.
Connected to the input terminal of this product (refer to section 4-3, Input/Output Terminal Function Description for input terminal)
In case the wiring length is short (2-3m), it can avoid malfunctions such as noise and surge.
Use twisted wire, otherwise use shielded wire.
When connecting the shield wire, connect the shielding sheath to the common terminal I 2 , and make sure that the shield wire is not placed close to the power wiring.
3. Specifications
item | specification | |||
Dancer winder converter | ||||
designation | ||||
LGFA-WB | ||||
Controller format | ||||
Invertor, AC Server-motor, DC Server-motor | ||||
Applicable models | ||||
everyone | Operating voltage and frequency | Single phase 220V (110V) 50/60H Z , internal switching when using 110V | ||
Allowable variation range | Power voltage fluctuation 180V-224V (90V~122V) Frequency fluctuation 47Hz -63Hz 220V at the time of shipment | |||
Control specifications | input | standard input | Level | DC 0V~±10V |
Impedance | 20KΩ | |||
return input | Level | DC 0V~±10V | ||
Impedance | 3.5KΩ |
item | specification | ||
Control specifications | output of power | Output signal | 0~+10V, 0~-10V |
volume | Up to 10mA (load resistance 1.2KΩ or more) | ||
voltage Precision | load fluctuations | Less than 0.1% at 50mA change (when output voltage is at maximum) | |
Power fluctuations | ±10% change, less than 0.1% (when output voltage is at maximum) | ||
temperature fluctuations | 0.2% or less when the change is 25℃±5℃ (when the output voltage is at maximum) | ||
Potentiometer: 1KΩ 1 turn (distance detection: Photosensor) Recommended Potentiometer: J-50S | |||
The output voltage (O 1 -O 2 ) is 0 to 3 times the reference speed setting voltage (I 1 -I 2 ). Adjustable | |||
The amount of compensation for the momentary change in Dancer is 0 to 10 times. Adjustable | |||
The time to compensate for the variation of Dancer according to the thickness of the coiled material, etc. Adjustable from 5 to 70 seconds | |||
The output signal polarity can be set to +(positive), -(negative), and ±3 types using the changeover switch. Optional. * Refer to the internal circuit adjustment in Article 6. | |||
±5V 10mA(Max) | |||
If terminal Z is connected to the common terminal (I 2 or O 2 ), the PI controller The integrator is maintained at 0V (i.e., reset). | |||
① DVM: Measurement range 00.00V~±19.99V / Error ±0.1V ② Lamp: Power indicator blue light / Overcurrent indicator red light | |||